LG aircon South Africa units are among the topmost reliable aircon brands in the country. In terms of output and ability to make use of energy to the most value, LG air conditioners are extremely reliable. Additionally, the units last very long while doing the most for your room temperature needs.
It is no surprise that LG airconditioners are extremely popular in South Africa. Furthermore, the units come with a 10-year warranty on outdoors. While most other aircons in South Africa offer a 5-year warranty, the LG aircon doubles that duration. The inverter LG aircons are worth looking at if you are planning on an energy saving aircon.
Related Content
LG aircon re-gas, repairs, and service
Samsung aircon re-gas, repairs and servicing
Alliance aircon re-gas, repairs and service
Daikin aircon re-gas, repairs and servicing
Dunham-bush aircon re-gas and services
LG Aircon Remote Control Symbols and Remote-Control Functions
Symbols in use for LG aircon South Africa units.
First, swich on and off – aircon symbol of turning on and off is normally shown as a vertical line
Second, LG air conditioner cool mode – shown as a snowflake to indicate the aircon cool mode.
Then, heat Mode – a sun is the symbol for lg ac unit heat mode
Dry Mode – a water drop symbol signals the lg ac unit dray mode, which lowers the humidity as the unit cools the room.
Fan Mode – allows the user to save electricity by using the fan such that there is no power cooling. It does, however, produce a lower cooling ability than the power cooling option.
Fan Speed – signal bars represent fan speed. The higher the bars, the faster the fan speed
Auto Function – The letter “A” represents auto mode. Once the room temperature reaches the set lit, the auto function maintains that temperature be it cooling or heating.
In addition, the Quiet Mode – a human showing silence is the symbol for quiet mode. It is for the lowest possible noise.
LG Remote Control Air Settings
Vertical and Vertical Air Swing – users can direct air swing in the vertical plane by making use of the symbol with many strokes of air. Likewise, the horizontal air swing symbol has many strokes in the vertical plane, and user can adjust air swing in the horizontal plane.
Air Ionizer – a pine tree represents air ionizer which helps to eliminate bacteria using negative ions.
Sleep Mode or Night Mode
lg aircon symbol of sleep mode represented by a sleeping star. This is also a common lg aircon function in use in South Africa.
LG error codes
If you experience error codes that you cannot self-diagnose, call air conditioner services for qualified air conditioner technicians to help bring your aircon to top performance. Gauteng Aircon will resolve any problematic lg aircon error codes for you anywhere in Gauteng, South Africa.
LG air aircon errors codes
Error Code Possible Cause
1 First code for probable temperature sensor issue
2 Inlet pipe sensor error message for indoor unit
4 Float switch error (optional)
5 Probable errors in communication between indoor unit and outdoor units
6 Indoor unit outlet pipe sensor error
9 Error code for indoor unit EPROM
10 Probable issue with indoor unit BLDC motor fan lock
12 Error code for indoor unit middle pipe sensor
21 DC Peak (IPM Fault); Compressor DC voltage was too high
22 Current Transformed (CT2) error; Alternating current (AC) input too high
23 DC Link Low Volt
25 AC Low/High Volt
26 DC Comp Position Error (not providing rotation), Locking
27 PSC Fault; Current to inverter compressor between AC and DC converter circuit too high
28 Inverter compressor DC voltage is too high
29 Inverter compressor amperage is too high
31 Current-to-current transformer (CT) thermistor is too low
32 Inverter Compressor Discharge Pipe (D-Pipe) Overheat
40 CT Sensor Error; Thermistor is disconnected or shorted out
41 D-Pipe Sensor INV is disconnected or shorted out
44 Outdoor Air Sensor is disconnected or shorted out
45 Middle thermistor of outdoor unit condenser coil is disconnected or shorted out
46 Outdoor unit suction line thermistor is disconnected or shorted out
48 Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out
53 Communication failure from outdoor unit to indoor unit
60 Outdoor unit printed circuit board (PCB) EPROM check sum error
61 Outdoor unit condenser coil temperature is too high
62 Outdoor unit inverter compressor PCB heat sink temperature is too high
63 Condenser coil pipe thermistor temperature is too low
65 Heat sink thermistor has disconnected or has shorted out